Sizing a roof water drain.
Sizing roof leaders.
The first step in sizing a roof drain is to calculate the surface area of the roof that the drains will be covering as well as the average hourly rainfall rate at the building location.
In sizing roof drains and storm drainage piping one half of the area of any vertical wall that diverts rainwater to the roof shall be added to the projected roof area for inclusion in calculating the required size of vertical conductors leaders and horizontal storm drainage piping.
Take the roof s total square footage and divide by the total square footage handled by one drain.
The result is the number of drains needed.
The above sizing data is offered as a guide only.
This reveals that the minimum size for the leader pipe is 5.
The next step is to determine each roof area that will be served by a separate leader drain pipe scupper or downspout.
In sizing roof drains and storm drainage piping one half of the area of any vertical wall that diverts rainwater to the roof shall be added to the projected roof area for inclusion in calculating the required size of vertical conductors leaders and horizontal storm drainage piping.